Название: A descrição matemática da detecção eletroanalítica dos íons de zinco em formas farmacêuticas de uso oftálmico, baseada na complexação de zinco com algumas bases de Schiff
Другие названия: The mathematical description for the electroanalytical detection of zinc ions in ophthalmic pharmaceutical forms, based on zinc complexation with some Schiff bases
Авторы: Tkach, V. V.
Kushnir, M. V.
de Oliveira, Sílvio C.
Parchenko, V. V.
Odyntsova, V. M.
Aksyonova, I. I.
Luganska, O. V.
Ivanushko, Y. G.
Lukanova, S. M.
Pishak, O. V.
Yagodynets', P. I.
Парченко, Володимир Володимирович
Одинцова, Віра Миколаївна
Аксьонова, Ілона Ігорівна
Ключевые слова: zinc
chemically modified electrodes
Schiff bases
complexes
electropolymerization
stable steady-state
Issue Date: 2020
Библиографическое описание: A descrição matemática da detecção eletroanalítica dos íons de zinco em formas farmacêuticas de uso oftálmico, baseada na complexação de zinco com algumas bases de Schiff / V. V. Tkach, M. V. Kushnir, Sílvio C. de Oliveira, V. V. Parchenko, V. M. Odyntsova, I. I. Aksyonova, O. V. Luganska, Y. G. Ivanushko, S. M. Lukanova, O. V. Pishak, P. I. Yagodynets' // Revista Colombiana de Ciencias Químico-Farmacéuticas. - 2020. - Vol. 49, N 3. - P. 710-719. - http://dx.doi.org/10.15446/rcciquifa.v49n3.91339.
Аннотация: An electroanalytical process of the quantitative determination of bivalent zinc ions over the novel Schiff bases in galvanostatic mode has been theoretically simulated. The correspondent mathematical model has been developed and analyzed by means of linear stability theory and bifurcation analysis. It was shown that the system is efficient from both electroanalytical and electrosynthetical points of view, as the steady-state is easily stabilized. Nevertheless, the oscillatory behavior in this system is more probable than in the classic case of the sensors, based on conducting polymers and other organic materials, as there are double electric layer influences, caused by complex formation.
URI: http://dspace.zsmu.edu.ua/handle/123456789/23412
Appears in Collections:Наукові праці. (Фармакогнозія)
Наукові праці. (Токсикологічна та неорганічна хімія)

Files in This Item:

File Description SizeFormat
aariverat,+art+8.pdf854,93 kBAdobe PDFView/Open
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback