DSpace О системе DSpace
 

IRZSMU >
Кафедри >
Кафедра стоматології післядіпломної освіти ННІПО >
Наукові праці. (Стоматологія післядіпломної освіти ННІПО) >

Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://dspace.zsmu.edu.ua/handle/123456789/24086

Название: Cross-Sectional Clinical Evaluation of Subantral Augmentation Using Nano Graft Composite: Implications for Implant Success
Авторы: Kosinov, O.
Manukhina, O. M.
Volchykhina, K. P.
Mishchenko, O. M.
Liutyi, A.
Ramanaviciute, A.
Ratautaite, V.
Ramanavicius, A.
Манухіна, Олеся Миколаївна
Волчихіна, Крістіна Петрівна
Міщенко, Олег Миколайович
Ключевые слова: bone composite
subantral augmentation
osteogenesis
bone regeneration
biocompatibility
dental implantation
Дата публикации: 2026
Библиографическое описание: Cross-Sectional Clinical Evaluation of Subantral Augmentation Using Nano Graft Composite: Implications for Implant Success / O. Kosinov, O. Manukhina, K. Volchykhina, O. Mishchenko, A. Liutyi, A. Ramanaviciute, V. Ratautaite, A. Ramanavicius // Dentistry Journal. - 2026. - Vol. 14, Iss. 1 . - P. 57. - https://doi.org/10.3390/dj14010057.
Аннотация: Objectives: This study aims to evaluate the efficacy of hydroxyapatite-tricalcium phosphate (HAP-TCP) as a bone substitute in subantral augmentation for dental implants. Specifically, it investigates the effects of HAP-TCP on bone quality, density, and integration with implants over time. Methods: A prospective controlled longitudinal study was conducted on 22 patients (39–75 years of age) undergoing subantral augmentation and dental implantation. A total of 52 sites of augmented bone and 67 sites of native bone were analyzed using computed tomography (CT) to assess bone density in Hounsfield Units (HU), insertion torque measurements, and the Misch classification for bone quality. Augmented and native bone measurements were compared within each patient. Results: The augmented bone exhibited an average density of 1132.6 ± 334.9 HU, which is significantly higher (45.9%) than the average density of native bone at 519.3 ± 395.0 HU. Insertion torque values in the HAP-TCP augmented sites averaged 35 N·cm, showing a 71.4% increase compared to adjacent native bone sites (25 N·cm). The study found notable improvements in bone homogeneity and vascularization within the augmented zones. Conclusion: HAP-TCP demonstrates significant potential as a reliable and effective synthetic bone substitute for subantral augmentation in dental implants. It yields higher radiodensity and insertion torque than adjacent native bone, while mitigating complications associated with autogenous grafts. These observational findings support the potential clinical use of HAP-TCP for sinus augmentation.
URI: http://dspace.zsmu.edu.ua/handle/123456789/24086
Располагается в коллекциях:Наукові праці. (Стоматологія післядіпломної освіти ННІПО)

Файлы этого ресурса:

Файл Описание РазмерФормат
dentistry-14-00057.pdf1,19 MBAdobe PDFПросмотреть/Открыть
View Statistics

Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2005 MIT and Hewlett-Packard - Обратная связь