IRZSMU >
Кафедри >
Кафедра органічної і біоорганічної хімії >
Наукові праці. (Органічна хімія) >
Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://dspace.zsmu.edu.ua/handle/123456789/13617
|
Название: | Development of a Novel, Fast, Simple HPLC Method for Determination of Atorvastatin and its Impurities in Tablets |
Авторы: | Shulyak, N. Piponski, M. Kovalenko, S. Stoimenova, T. B. Balkanov, T. El-Subbagh, H.I. Drapak, I. Omotosho, J.O. Logoyda, L. Коваленко, Сергій Іванович |
Ключевые слова: | atorvastatin impurities liquid chromatography method optimization tablets |
Дата публикации: | 2021 |
Библиографическое описание: | Development of a Novel, Fast, Simple HPLC Method for Determination of Atorvastatin and its Impurities in Tablets / N. Shulyak, M. Piponski, S. Kovalenko,T. B. Stoimenova, T. Balkanov, H. I. El-Subbagh, I. Drapak, J. O. Omotosho, L. Logoyda // Scientia Pharmaceutica. - 2021. - Vol. 89, № 2. - P. 16. - https://doi.org/10.3390/scipharm89020016 |
Аннотация: | Our main target and concept was to develop a method for the determination of the most
prescribed antilipemic drug, atorvastatin, together with its related substances, with a single sample
preparation and during a single chromatographic run, in the shortest possible period of time, with
the lowest possible mobile phase consumption. A new rapid, simple chromatographic method for
the determination of atorvastatin and its main specified impurities was developed, using different
chromatographic columns. With this new concept of a mobile phase and a powerful core–shell, or
a superficially porous silica-based column, satisfactory results for targeted parameters, such as
critical peak resolution, run time length, and column backpressure, were achieved. The analysis is
performed within a run duration of less than 15 minutes, which is about six times shorter than the
official European Pharmacopoeia method. The chromatogram performances suggests that the
method limit of quantification (LOQ) can be about 7 times lower, and the limit of detection (LOD)
about 20 times lower, using an injection volume of only 2 μl. This was confirmed by the performed
method validation in accordance with the International Conference on Harmonization (ICH)
guideline for the validation of analytical procedures Q2(R1), where the selectivity, linearity,
accuracy, precision, limit of quantification, and limit of detection were tested and confirmed. |
URI: | http://dspace.zsmu.edu.ua/handle/123456789/13617 |
Располагается в коллекциях: | Наукові праці. (Органічна хімія)
|