DSpace О системе DSpace
 

IRZSMU >
Кафедри >
Кафедра органічної і біоорганічної хімії >
Наукові праці. (Органічна хімія) >

Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://dspace.zsmu.edu.ua/handle/123456789/13617

Название: Development of a Novel, Fast, Simple HPLC Method for Determination of Atorvastatin and its Impurities in Tablets
Авторы: Shulyak, N.
Piponski, M.
Kovalenko, S.
Stoimenova, T. B.
Balkanov, T.
El-Subbagh, H.I.
Drapak, I.
Omotosho, J.O.
Logoyda, L.
Коваленко, Сергій Іванович
Ключевые слова: atorvastatin
impurities
liquid chromatography
method optimization
tablets
Дата публикации: 2021
Библиографическое описание: Development of a Novel, Fast, Simple HPLC Method for Determination of Atorvastatin and its Impurities in Tablets / N. Shulyak, M. Piponski, S. Kovalenko,T. B. Stoimenova, T. Balkanov, H. I. El-Subbagh, I. Drapak, J. O. Omotosho, L. Logoyda // Scientia Pharmaceutica. - 2021. - Vol. 89, № 2. - P. 16. - https://doi.org/10.3390/scipharm89020016
Аннотация: Our main target and concept was to develop a method for the determination of the most prescribed antilipemic drug, atorvastatin, together with its related substances, with a single sample preparation and during a single chromatographic run, in the shortest possible period of time, with the lowest possible mobile phase consumption. A new rapid, simple chromatographic method for the determination of atorvastatin and its main specified impurities was developed, using different chromatographic columns. With this new concept of a mobile phase and a powerful core–shell, or a superficially porous silica-based column, satisfactory results for targeted parameters, such as critical peak resolution, run time length, and column backpressure, were achieved. The analysis is performed within a run duration of less than 15 minutes, which is about six times shorter than the official European Pharmacopoeia method. The chromatogram performances suggests that the method limit of quantification (LOQ) can be about 7 times lower, and the limit of detection (LOD) about 20 times lower, using an injection volume of only 2 μl. This was confirmed by the performed method validation in accordance with the International Conference on Harmonization (ICH) guideline for the validation of analytical procedures Q2(R1), where the selectivity, linearity, accuracy, precision, limit of quantification, and limit of detection were tested and confirmed.
URI: http://dspace.zsmu.edu.ua/handle/123456789/13617
Располагается в коллекциях:Наукові праці. (Органічна хімія)

Файлы этого ресурса:

Файл Описание РазмерФормат
scipharm-89-00016.pdf2,75 MBAdobe PDFПросмотреть/Открыть
View Statistics

Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2005 MIT and Hewlett-Packard - Обратная связь