Название: Development of a method for determining the morpholinium thiazotate using more economic and green GC/MS assay with an fid detector
Авторы: Belikova, A.
Materienko, A.
Sidorenko, L.
Chornyi, V.
Korzh, I.
Kucherenko, L. I.
Kotvitska, A.
Burdulis, D.
Georgiyants, V.
Кучеренкоб Людмила Іванівна
Ключевые слова: HPLC
GC-FID
method development
analytical eco-scale
cost analysis
environmental
AGREE scale
Дата публикации: 2022
Библиографическое описание: Development of a method for determining the morpholinium thiazotate using more economic and green GC/MS assay with an fid detector / A. Belikova, A. Materienko, L. Sidorenko, V. Chornyi, I. Korzh, L. Kucherenko, A. Kotvitska, D. Burdulis, V. Georgiyants // ScienceRise: Pharmaceutical Science. - 2022. - N 3. - P. 4-11. - https://doi.org/10.15587/2519-4852.2022.259879.
Аннотация: One of the main steps in the pharmaceutical development of drugs is the choice of quality control methods. The correctness of the method must be confirmed by validation. In addition, manufacturers take into account various economic and environmental factors. It is especially important to determine the above aspects for domestic and promising drugs, such as the morpholinium thiazotate. The aim. During the development of methods for the routine analysis of medicinal products, attention should be paid to efficiency of analysis, budget, as well as their impact to the environment. Because of this reason, not only new methods for routine analysis should be developed. It is important this methods must be environmentally-friendly and cost-efficient. Materials and methods. The determination of the morpholinium thiazotate was carried out by HPLC using the SunFire C18 (150×4.6 mm, 5.0 μm) and gas chromatography with a flame ionization detector using the Rxi-5 ms (30 m long, 0.25 mm outer diameter and 0.25 μm liquid stationary phase thickness). Results. Various chromatographic methods for the routine quantitative analysis of morpholinium thiazotate were developed. The most suitable conditions for sample preparation were established. Proposed methods were compared to find the most ecological and economic. Conclusions. Proposed methods were accurate and reliable. However, an environmental impact assessment showed that GC-FID is a more environmentally friendly and economical method of analysis. Using 12 Principles of green analytical chemistry, the overall “analytical GREEnness (AGREE)” scale for the proposed analytical approach was computed 0.72, showing the good greener nature of the proposed analytical approach
URI: http://dspace.zsmu.edu.ua/handle/123456789/18266
Располагается в коллекциях:Наукові праці. (Фармацевтична хімія)

Файлы этого ресурса:

Файл Описание РазмерФормат
259879-Article Text-599378-1-10-20220630.pdf447,36 kBAdobe PDFПросмотреть/Открыть
View Statistics

Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2005 MIT and Hewlett-Packard - Обратная связь