DSpace О системе DSpace
 

IRZSMU >
Кафедри >
Кафедра стоматології післядіпломної освіти ННІПО >
Наукові праці. (Стоматологія післядіпломної освіти ННІПО) >

Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://dspace.zsmu.edu.ua/handle/123456789/23489

Название: Case report of using partially epithelialized connective tissue graft for peri-implant soft tissue augmentation simultaneously with dental implant placement
Авторы: Demyanov, S. O.
Dubnov, A.
Дем'янов, Сергій Олександрович
Ключевые слова: connective tissue
graft
de-epithelization
periimplant soft tissue
dental implant
Дата публикации: 2024
Библиографическое описание: Demyanov S. Case report of using partially epithelialized connective tissue graft for peri-implant soft tissue augmentation simultaneously with dental implant placement / S. Demyanov, A. Dubnov // Український Стоматологічний Журнал. - 2024. - Т. 3, N 1/2. - С. 162-172. - https://doi.org/10.56569/UDJ.3.1-2.2024.162-172.
Аннотация: Objective. To demonstrate clinical option of using partially epithelialized connective tissue graft for periimplant soft tissue augmentation simultaneously with dental implant placement procedure to enhance peri-implant esthetic profile and optimize soft-tissue stability for further prosthetic rehabilitation. Case report. Patient 46 years old patient referred to the dental clinic with complaints regarding condition of mandibular fixed denture, which he was using already for 9 years. Also, patient informed dentist that he wants to improve his chewing ability by restoring edentulous distal regions of mandible with implant-borne fixed dentures. Patient previous denture was gently deattached from mandibular abutment teeth while not altering periodontal conditions of any of them during procedure. All the targeted and periodontal treatment was provided based on clinical need. Tissue level implants were placed at the projection of teeth 4.5-4.6 and 3.6-3.7 due to the conventional implant placement protocol. To compensate soft tissue collapse within the implant placement region it was decided to augment such with partially epithelialized connective tissue graft. Graft was shaped, prepared and partially de-epithelialized to overcome issue of volume excess using standard technique. Partially epithelialized connective tissue graft was positioned carefully with the manner of the epithelial portion covering dental implant part, while connective tissue portion was facing inner surface of separated flap, and was covered by a flap. Modified horizontal mattress sutures were used to secure connective tissue graft at the place while retaining its primarily established positions and guaranteeing tension-free flap closure around installed healing abutments. Results of final rehabilitation outcomes with satisfactory appearance of the soft tissue condition around fixed prosthetic construction were achieved at the end of the treatment.
URI: http://dspace.zsmu.edu.ua/handle/123456789/23489
Располагается в коллекциях:Наукові праці. (Стоматологія післядіпломної освіти ННІПО)

Файлы этого ресурса:

Файл Описание РазмерФормат
UDJ_3_1-2_2024_Demyanov_162-172.pdf4,54 MBAdobe PDFПросмотреть/Открыть
View Statistics

Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2005 MIT and Hewlett-Packard - Обратная связь